Restart the robot with the newest URDF

Before you start calibrating the robot, the robot should be started from the newest urdf file that is available. In the '/etc/ros/electric/urdf' folder (there is a specific folder for each distro), you find a number of urdf files called 'robot_uncalibrated_x.x.x.xml'. Modify the symbolic link 'robot.xml' to point to the newest uncalibrated urdf file (as root):

cd /etc/ros/electric/urdf
ln -sf robot_uncalibrated_x.x.x.xml robot.xml

You can verify the current symlink using the following command:

ls -la /etc/ros/electric/urdf/robot.xml

Click here for special instructions if you run an old C-turtle alpha

Power cycle the MCBs using pr2_dashboard, and then restart the robot:

<<Use Dashboard to put LRB Breakers into Disable, and then into Enable>>
sudo robot stop
sudo robot start

http://www.ros.org/wiki/pr2_calibration/Tutorials/Calibrating the PR2?action=AttachFile&do=get&target=dashboard_disable.png

Calibrate Camera Intrinsics

The stereocamera and forearm cameras must be calibrated before running the full robot calibration. See the Calibrating the PR2's Cameras Tutorial

Capture Data

Log into the robot with X-Forwarding, and start the data capture application

ssh prx -X
robot start
roslaunch pr2_calibration_launch capture_data.launch

If your robot has a kinect/xtion mounted on its head, you also need to launch the node for that:

roslaunch /etc/ros/openni_head.launch

Note: The texture projector must be off for data capture to work!

This will start all the processing nodes, along with the data capture executive. It will also open 8 image_view windows. Each provides the state of the checkerboard detector for each stream. Each currently active sensor must consistently detect the checkerboard in order for the executive to capture a sample.

Follow the command line prompts to go through the calibration.

Understanding the sensors streams

Once you start capture_data.launch, 8 image_view windows will open and will look like the following (although not as neatly arranged):

http://www.ros.org/wiki/pr2_calibration/SubTutorials/Capture Data?action=AttachFile&do=get&target=gui_start.png

Notice that both forearm camera streams have been grayed out. Once the executive activates these streams later in the capture process, you will begin to see data from these cameras.

Checkerboard Detector

There is an openCV checkerboard detector running on each sensor stream. The result of the detector is shown as circles in each image frame (see image below). A successful detection is signified by a green circle at every corner, along with a red circle at one corner. Partial failures show red circles, while complete failures show no circles at all.

http://www.ros.org/wiki/pr2_calibration/SubTutorials/Capture Data?action=AttachFile&do=get&target=cb_detect_fail.png

Capturing Large Checkerboards

During this phase, the application will prompt you to place a large checkerboard in view of all the head cameras and tilting laser. After positioning the board in a good location, press <enter> to begin capture. The app will either detect the checkerboard, or timeout in 40 seconds.

It is suggested that you collect 4 large checkerboards, each about 2 to 3 meters away from the robot. If you are feeling ambitious, you can collect 3 more checkerboards (left, centered and right) that are 1.5 to 2 meters from the robot.

Note: The checkerboard on the floor can often be very tricky to capture, due to glare from overhead lighting. If this sample is causing trouble, feel free to skip it.

http://www.ros.org/wiki/pr2_calibration/SubTutorials/Capture Data?action=AttachFile&do=get&target=calibration.png

Teleop Joystick

Both stereo pairs (along with the tilting laser) must detect the large checkerboard in order to successfully capture a sample. Thus, you will definitely have to move the head around in order the see the checkerboard.

The teleop joystick already comes up with the capture_data app. Thus, you can use the joystick to move the head around as needed (and base around as needed)

Understanding the Tilting Laser Intensity Images

For each scan, the tilting laser provides both range and intensity data along a horizontal line. We then stack intensity data from successive together, creating the image. Note that the Hokuyo UTM-30lx scans from right to left, resulting in the intensity image being flipped horizontally.

Specular Reflections

Placing the large checkerboard close to orthogonal to the laser ray will result in very bright specular reflections. This can be solved by turning the checkerboard until there is no bright spot in the intensity image.

http://www.ros.org/wiki/pr2_calibration/SubTutorials/Capture Data?action=AttachFile&do=get&target=specular.png

Finish collecting Large Checkerboards

Once you've collected enough large checkerboards, press "N" at the prompt to continue. Don't forget to remove the large checkerboard from the robot's view, as it might mess up the next step in the calibration.

Capturing Left Hand Checkerboard

You should now see the left arm move in view of the head cameras. Place the 5x4 checkerboard in the left gripper. In order to ensure that the checkerboard doesn't move during the calibration procedure. The gripper pads should completely contact the non-slip tape on the checkerboard plate (see image below). You can use the joystick to close the gripper. The left D-pad button on the joystick will close the gripper while the the right D-pad button on the joystick will open the gripper.

Also, make sure to hide the large checkerboard from the view of the robot, since it can confuse the checkerboard detector.

Press <enter> once the checkerboard is securely held in the left gripper.

http://www.ros.org/wiki/pr2_calibration/SubTutorials/Capture Data?action=AttachFile&do=get&target=hand_cb.png

WARNING: Once the checkerboard is firmly grasped by the gripper and robot has started collecting data, DO NOT DISTURB THE GRASP. The calibration procedure estimates the offset from the gripper to the CB, and assumes a constant grasp throughout the calibration procedure. If the checkerboard hits anything, the grasp can change, and the calibration data capture must be restarted.

Capturing Right Hand Checkerboard

Move the checkerboard from the left hand to the right. Press <enter> once it is securely held in the right gripper.

Cleanup

You will see a message at the console once the execute has completed. Remove the checkerboard from the gripper.

You now have a bagfile at /tmp/pr2_calibration/cal_measurements.bag with calibration data. You can always use "rosbag info" to see how many calibration samples you collected.

Estimate the URDF

This step will run the nonlinear optimization that estimates the system parameters, and then generate a new URDF in the current directory.

This step runs twice as fast when the robot isn't running. It is suggested that you bring down the robot and then start your own core (if you don't have a core running, some of the scripts will unexpectedly hang).

robot stop
roscore

Now, in another terminal (make sure you're in a directory where you have write-permissions), start the estimation process. This will take a while to run.

rosrun pr2_calibration_launch estimate_pr2_beta_urdf.sh

After each calibration step completes, you'll see what the RMS error is for each sensor. Each step will take 5-10 minutes.

It will take approximately 25 minutes for the optimization to complete. This will put the generated URDF (robot_calibrated.xml) in the current working directory.

If you want to view the results, you can look at an experimental scatter plot of various errors.

rosrun pr2_calibration_launch view_head_laser_scatter.sh
rosrun pr2_calibration_launch view_head_arm_scatter.sh
rosrun pr2_calibration_launch view_forearm_scatter.sh

When viewing the scatter plots, make sure the errors on the first plot (head_laser) are within 20px of the (0,0) point, and the errors on the remaining plots are within 10px of the (0,0) point. If the plots show large errors, or bimodal distributions, your calibration will not be very good.

Update the system

Update the URDF

For people to start using this new URDF, /etc/ros/[DISTRO]/urdf/robot.xml should be symlinked to your newly generated URDF (robot_calibrated.xml) by your PR2 Administrator.

cp robot_calibrated.xml /etc/ros/[DISTRO]/urdf/robot_calibrated_[DATE]_[VERSION].xml
ln -fs /etc/ros/[DISTRO]/urdf/robot_calibrated_[DATE]_[VERSION].xml /etc/ros/[DISTRO]/urdf/robot.xml

Generally, the [VERSION] field is the version of the pr2_common stack, which has pr2_description, so you can compare your URDF.

Update Stereo Baselines

The stereo baselines are stored on the wge100 cameras, so their eeprom needs to be updated.

While the robot is running, call the following:

rosrun pr2_calibration_launch write_pr2_cam_intrinsics.sh

Click here for special instructions if you run an old C-turtle alpha

The motor controller boards (MCBs) store the joint calibration data. Thus, the joints won't recalibrate unless you power cycle the MCBs. Power cycle the MCBs using pr2_dashboard.

http://www.ros.org/wiki/pr2_calibration/Tutorials/Calibrating the PR2?action=AttachFile&do=get&target=dashboard_disable.png

Now restart the robot:

robot stop
robot start

You will now see the robot start up using its new calibrated reference positions.

Calibration-dependent configuration

Some configuration files depend on the pr2 calibration, and become invalid after re-calibrating the pr2. To make sure nobody uses the invalid files, it is best to delete them:

rm /etc/ros/plugs/calibration.yaml

This will remove the capability of your PR2 to plug itself into an outlet autonomously. If you care about this capability, you can create a new calibration for plugging in, following instructions that will appear in a pr2_plugs tutorial.

Calibration Sanity Check

Before shipping a robot, Willow Garage does a calibration sanity check using rviz. The sanity check is outlined at pr2_bringup_tests/calibration_bringup

Troubleshooting

See the pr2_calibration/Troubleshooting page for help in resolving any issues